Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 8.168
1.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Article En | MEDLINE | ID: mdl-38722121

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Aortic Valve , Echocardiography, Transesophageal , Humans , Female , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Middle Aged , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery
2.
Ann Card Anaesth ; 27(1): 53-57, 2024 Jan 01.
Article En | MEDLINE | ID: mdl-38722122

ABSTRACT: Aortic valve (AV) repair is the desired surgical treatment option for young patients with aortic regurgitation (AR). It is considered as a class I indication for the surgical treatment of severeAR. The success of an AV repair depends on the detailed intraoperative transesophageal echocardiographic (TEE) examination which should fulfil the information required by the surgeon. The objective of this echo round is to describe the role of intraoperative TEE in systematic evaluation of the AV, before and after repair.


Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Monitoring, Intraoperative , Humans , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Child , Monitoring, Intraoperative/methods
3.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article En | MEDLINE | ID: mdl-38608189

OBJECTIVES: Repair of the bicuspid aortic valve (BAV) has evolved in the past 25 years. The aim of this study was to review and analyse the long-term durability of isolated BAV repair with particular focus on commissural orientation (CO). METHODS: All patients who underwent BAV repair for severe aortic regurgitation between October 1998 and December 2022 were included. The study group consists of all patients operated after 2009, i.e. since CO modification. The control group includes patients who were operated before 2009. CO was classified as symmetric, asymmetric and very asymmetric. RESULTS: Overall, 594 adult patients (93% male; mean age 42 years) were included. At 15 years, survival was 94.8% [standard deviation (SD): 2.2]; freedom from reoperation was 86.8% (SD: 2.3). Freedom from aortic insufficiency ≥II was 70.8% (SD: 4.7) at 15 years. Modification of CO by sinus plication was performed in 200 (33.7%) instances. Using competing risks analysis, the absence of effective height measurement (P = 0.018), very asymmetric CO (P = 0.028), the presence of calcification (P < 0.001), the use of pericardial patch (P < 0.001), the use of subcommissural sutures (P < 0.001) and preoperative endocarditis (P = 0.005) were identified as independent predictors for reoperation. Follow-up was 97% complete (4228 patient-years); mean follow-up was 7 years (SD: 5). CONCLUSIONS: Isolated BAV repair leads to good survival and durability in all morphologic types if cusp repair is guided by effective height, suture annuloplasty is performed, and CO is modified using sinus plication in asymmetrical valves. Very asymmetrical valves may should be treated with a lower threshold for replacement.


Aortic Valve Insufficiency , Aortic Valve , Bicuspid Aortic Valve Disease , Humans , Male , Bicuspid Aortic Valve Disease/surgery , Aortic Valve/surgery , Aortic Valve/abnormalities , Adult , Female , Aortic Valve Insufficiency/surgery , Middle Aged , Retrospective Studies , Treatment Outcome , Reoperation/statistics & numerical data , Heart Valve Diseases/surgery , Young Adult , Follow-Up Studies
4.
Inn Med (Heidelb) ; 65(5): 431-438, 2024 May.
Article De | MEDLINE | ID: mdl-38635087

The pathophysiology of aortic valve diseases is of predominantly degenerative nature, characterized by calcific aortic valve stenosis, which is associated with a reduction in prognosis. The prevalence of aortic valve insufficiency also increases with advancing age. Timely causal treatment is crucial in the management of aortic valve diseases. Following the indication for intervention, the heart team plays a central role in evaluating the results and making therapeutic decisions that consider the patient's preferences. In the assessment of treatment options, considerations regarding the long-term perspective are particularly crucial, especially in younger patients. The most common therapeutic approach for aortic valve diseases is the introduction of a new valve prosthesis. In the majority of cases, this is now achieved through catheter-based implantation of a bioprosthetic heart valve, known as transcatheter aortic valve implantation (TAVI). Open surgical aortic valve replacement (AVR) is favored in younger patients with low surgical risk or in the case that TAVI is not feasible. In AVR, both biological and the longest-lasting mechanical prosthesis types are used. Surgical repair techniques are primarily applied in cases of aortic valve regurgitation. Notably, TAVI, as well as surgical procedures for the treatment of aortic valve diseases, have undergone significant advancements in recent years, including expanded indications for TAVI and, on the surgical side, in particular the development of minimally invasive surgical techniques.


Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Aortic Valve/pathology , Heart Valve Prosthesis , Aortic Valve Disease/surgery , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/instrumentation , Aortic Valve Stenosis/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Bioprosthesis
5.
Surg Innov ; 31(3): 256-262, 2024 Jun.
Article En | MEDLINE | ID: mdl-38565982

OBJECTIVE: In this case report, the auxiliary role of deep learning and 3-dimensional printing technology in the perioperative period was discussed to guide transcatheter aortic valve replacement and coronary stent implantation simultaneously. CASE PRESENTATION: A 68-year-old man had shortness of breath and chest tightness, accompanied by paroxysmal nocturnal dyspnea, 2 weeks before presenting at our hospital. Echocardiography results obtained in the outpatient department showed severe aortic stenosis combined with regurgitation and pleural effusion. The patient was first treated with closed thoracic drainage. After 800 mL of pleural effusion was collected, the patient's symptoms were relieved and he was admitted to the hospital. Preoperative transthoracic echocardiography showed severe bicuspid aortic valve stenosis combined with calcification and aortic regurgitation (mean pressure gradient, 42 mmHg). Preoperative computed tomography results showed a type I bicuspid aortic valve with severe eccentric calcification. The leaflet could be seen from the left coronary artery plane, which indicated an extremely high possibility of coronary obstruction. After preoperative imaging assessment, deep learning and 3-dimensional printing technology were used for evaluation and simulation. Guided transcatheter aortic valve replacement and a coronary stent implant were completed successfully. Postoperative digital subtraction angiography showed that the bioprosthesis and the chimney coronary stent were in ideal positions. Transesophageal echocardiography showed normal morphology without paravalvular regurgitation. CONCLUSION: The perioperative guidance of deep learning and 3-dimensional printing are of great help for surgical strategy formulation in patients with severe bicuspid aortic valve stenosis with calcification and high-risk coronary obstruction.


Aortic Valve Stenosis , Deep Learning , Printing, Three-Dimensional , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Male , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Stents , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/abnormalities , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging
6.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article En | MEDLINE | ID: mdl-38577923

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Aortic Dissection , Aortic Valve Insufficiency , Aortic Valve , Blood Vessel Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aortic Dissection/surgery , Aortic Dissection/diagnostic imaging , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Treatment Outcome , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Prosthesis Design , Blood Vessel Prosthesis , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm/surgery , Aortic Aneurysm/diagnostic imaging , Aortography
7.
Khirurgiia (Mosk) ; (4): 141-145, 2024.
Article Ru | MEDLINE | ID: mdl-38634595

Aortic root remodeling using the Florida sleeve technique was proposed as a simpler alternative to classical reconstructive interventions in patients with aortic root aneurysm without aortic insufficiency. We present a 10-year result of valve-sparing surgical treatment using the Florida sleeve technique in a patient with connective tissue dysplasia and aortic root aneurysm.


Aortic Aneurysm, Thoracic , Aortic Root Aneurysm , Aortic Valve Insufficiency , Connective Tissue Diseases , Humans , Aortic Valve/surgery , Treatment Outcome , Aortic Valve Insufficiency/surgery , Aortic Aneurysm, Thoracic/surgery , Connective Tissue
8.
Echocardiography ; 41(4): e15817, 2024 Apr.
Article En | MEDLINE | ID: mdl-38648213

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital disease. The clinical characteristics of this disease remain unclear except for those in relatively young patients reported from tertiary referral hospitals. The aim of this study was to determine the clinical features of QAV in a regional population. METHODS AND RESULTS: We retrospectively investigated 25 340 consecutive patients over middle age (median age, 73 (IQR 65-80) years; range, 45-102 years) who underwent transthoracic echocardiography (TTE) at our institute during the period from April 2008 to December 2023. Eight (0.032%) of the patients (median age, 65 years; range, 47-91 years) were diagnosed with QAV. Six patients suffered from aortic regurgitation (AR), and one patient had mild aortic stenosis at the time of QAV diagnosis. Two patients who had severe AR at referral underwent aortic valve surgery. The severity of AR in the other patients was moderate or less. During a median follow-up period of 27 months (range, 1-171 months), none of the patients other than above two patients had cardiac events. One patient died from a non-cardiac cause at 94 years of age. CONCLUSIONS: Patients diagnosed with QAV after middle age, who do not exhibit severe valve insufficiency at the time of diagnosis, may not experience worse clinical outcomes. However, further research is required for a better understanding of the long-term outcomes.


Aortic Valve , Echocardiography , Humans , Female , Male , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aged , Retrospective Studies , Middle Aged , Aged, 80 and over , Echocardiography/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Follow-Up Studies
9.
Tex Heart Inst J ; 51(1)2024 Apr 30.
Article En | MEDLINE | ID: mdl-38686682

Quadricuspid aortic valve is a rare congenital cardiac anomaly with an incidence of 0.008% to 0.043%. Its clinical course varies depending on cusp anatomy, function, and associated cardiac malformations. It frequently progresses to aortic valve regurgitation that may require surgical valve replacement. Detection has shifted from incidental discovery during autopsies or cardiac surgeries in the early 20th century to various cardiac imaging methods in recent decades. In addition to contributing to the literature, this report supports the use of transesophageal echocardiography more liberally to detect aortic valve abnormalities. The case presents a 48-year-old female patient with an incidentally discovered quadricuspid aortic valve.


Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Heart Defects, Congenital , Incidental Findings , Humans , Female , Aortic Valve/abnormalities , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Middle Aged , Echocardiography, Transesophageal/methods , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/etiology , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/surgery , Heart Defects, Congenital/diagnostic imaging , Predictive Value of Tests , Heart Valve Prosthesis Implantation , Echocardiography, Doppler, Color
10.
J Am Heart Assoc ; 13(9): e032532, 2024 May 07.
Article En | MEDLINE | ID: mdl-38686861

BACKGROUND: This study was performed to determine cusp causes of aortic regurgitation in patients with tricuspid aortic valves without significant aortic dilatation and define cusp pathologies amenable to surgical repair (aortic valve repair [AVr]) versus aortic valve replacement. METHODS AND RESULTS: We retrospectively reviewed surgical reports of consecutive adults with tricuspid aortic valves undergoing surgery for clinically significant aortic regurgitation within a prospective registry from January 2005 to September 2019. Valvular mechanisms were determined by systematic in vivo intraoperative quantification methods. Of 516 patients, 287 (56%) underwent repair (AVr; mean±SD age, 59.9±12.4 years; 81% men) and 229 (44%) underwent replacement (aortic valve replacement; mean±SD age, 62.8±13.8 years [P=0.01 compared to AVr]; 67% men). A single valvular mechanism was present in 454 patients (88%), with cusp prolapse (46%), retraction (24%), and perforation (18%) being the most common. Prolapse involved the right cusp in 86% of cases and was more frequent in men (P<0.001). Two-dimensional transesophageal echocardiography accuracy for predicting mechanisms was 73% to 82% for the right cusp, 55% to 61% for the noncoronary cusp, and 0% for the left-coronary cusp. Cusp prolapse, younger age, and larger patient size were associated with successful AVr (all P<0.03), whereas retraction, perforation, older age, and concomitant mitral repair were associated with aortic valve replacement (all P<0.03). CONCLUSIONS: Right cusp prolapse is the most frequent single valvular mechanism in patients with tricuspid aortic valve aortic regurgitation, followed by cusp retraction and perforation. The accuracy of 2-dimensional transesophageal echocardiography is limited for left and noncoronary cusp mechanistic assessment. Prolapse is associated with successful AVr, whereas retraction and perforation are associated with aortic valve replacement. With systematic intraoperative quantification methods and current surgical techniques, more than half of tricuspid aortic valve aortic regurgitation cases may be successfully repaired.


Aortic Valve Insufficiency , Aortic Valve , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation , Humans , Male , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Middle Aged , Female , Retrospective Studies , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aged , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Treatment Outcome , Registries , Cardiac Valve Annuloplasty/methods
12.
Article En | MEDLINE | ID: mdl-38522870

Half a century after the first pulmonary autograft operation (Ross operation), performed in 1967 by Donald Ross in central London, there is a very strong conviction that the Ross operation is the best available valve substitute today, not only for children, but also for younger and older adults. The Ross operation has stimulated a lot of science to do with tissue-engineering and biology of heart valves, which is a promising avenue for the future. For one of us (M.Y.), it has certainly been a privilege to be associated with the comeback of the Ross operation.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Pulmonary Valve , Child , Humans , Aged , Autografts/surgery , Pulmonary Valve/surgery , Transplantation, Autologous , Reoperation , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Treatment Outcome
13.
Article En | MEDLINE | ID: mdl-38522871

While it is the main viable option in the growing child and young adult, the Ross procedure has expanded its applicability to older patients, for whom long-term results are equivalent, if not superior, to prosthetic aortic valve replacement. Strategies aiming at mitigating long-term autograft failure from root enlargement and valve regurgitation have led some to advocate for root reinforcement with prosthetic graft material. On the contrary, we will discuss herein the rationale for a tailored approach to the Ross procedure; this strategy is aimed at maintaining the natural physiology and interplay between the various autograft components. Several technical maneuvers, including careful matching of aortic and autograft annuli and sino-tubular junction as well as external support by autologous aortic tissue maintain these physiologic relationships and the viability of the autograft, and could translate in a lower need for late reintervention because of dilation and/or valve regurgitation.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Diseases , Pulmonary Valve , Child , Young Adult , Humans , Autografts , Aortic Valve Insufficiency/surgery , Dilatation/adverse effects , Transplantation, Autologous/adverse effects , Transplantation, Autologous/methods , Aortic Valve/surgery , Heart Valve Diseases/complications , Heart Valve Diseases/surgery , Reoperation , Pulmonary Valve/surgery , Aortic Valve Stenosis/surgery , Treatment Outcome , Retrospective Studies
14.
Article En | MEDLINE | ID: mdl-38522872

The Ross procedure is an excellent option for aortic valve replacement resulting in outstanding hemodynamic performance and the ability to avoid systemic anticoagulation. The long-term durability of the autograft is generally good but concerns for later aortic root dilation with ensuing neoaortic insufficiency have prompted efforts to stabilize the autograft, root, sinuses and Sino-tubular junction in order to delay or entirely avoid late reinterventions on the neoaortic root. We have employed an inclusion technique, supporting the Auto-graft in a Terumo Gelweave™ Valsalva graft. We performed a retrospective study of all 129 patients undergoing the Ross procedure from 1992 to 2019 at Children's Wisconsin. Fifty-one underwent the supported Ross (SR) and 78 underwent unsupported Ross (UR). Structured clinical data was collected and echocardiograms were reviewed. Median follow-up was 4.9 years (up to 22.6 years) for UR patients and 3.6 years (up to 11.4 years) for SR patients. In order to provide a fair comparison, we sub -analyzed patients aged 10 to 18 years who underwent the Ross procedure, 16 who underwent the UR and 18 patients who underwent the SR. Change in aortic annulus diameter (P = 0.002), aortic sinus diameter (P = 0.001) change in left ventricular function (P = 0.039) and change in aortic insufficiency (P = 0.008) were all worse in UR. The SR is simple, reproducible, and predictable. It seems to prevent change in annulus diameter, sinus diameter and to reduce late neoaortic insufficiency. Longer follow-up with a larger group of patients is required to draw definitive conclusions.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Pulmonary Valve , Child , Humans , Autografts , Retrospective Studies , Dilatation , Transplantation, Autologous , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Dilatation, Pathologic , Pulmonary Valve/surgery , Follow-Up Studies
15.
BMC Cardiovasc Disord ; 24(1): 163, 2024 Mar 19.
Article En | MEDLINE | ID: mdl-38504187

BACKGROUND: Aortic valve reconstruction using glutaraldehyde-treated autologous pericardium, also called Ozaki procedure, is a surgical procedure for patients with aortic valve disease. Gratifying results have been reported in adult patients, however, limited published data is available in paediatric population. This study looked at clinical characteristics and early outcomes of children who underwent Ozaki procedure at our Institute. METHODS: This was a retrospective descriptive study conducted on children who underwent aortic valve reconstruction at Jakaya Kikwete Cardiac Institute (JKCI) from January 2019 through December 2022. Medical records of these children were reviewed to extract data on demographics, clinical characteristics, redo surgical interventions and survival. RESULTS: A total of 10 children underwent Ozaki procedure during the study period. Eight children had severe aortic regurgitation while 2 had severe aortic stenosis preoperatively. All children had either none or trivial aortic regurgitation immediately after surgery. None of them had redone operations throughout the follow-up period. There was no in-hospital mortality, however, one child died one-year after surgery. The mean follow-up period was 1.6 years with the longest follow-up time of 4 years. CONCLUSION: Ozaki procedure showed encouraging early results among children with aortic valve disease who underwent surgical repair by this technique. Future studies with larger sample sizes and longer follow up periods to evaluate long-term results in this population are recommended.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Adult , Child , Humans , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Retrospective Studies , Tanzania , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Pericardium/transplantation , Treatment Outcome
16.
J Cardiothorac Surg ; 19(1): 156, 2024 Mar 26.
Article En | MEDLINE | ID: mdl-38532504

This is a case report of a 78-year-old male who underwent a sub-coronary aortic valve and root replacement due to valve dehiscence and aortic root pseudoaneurysm. The patient had complex anomalous coronary anatomy and had undergone a previous tissue aortic valve replacement in 2013. The patient made an uneventful recovery and was discharged from the hospital five days later. The authors suggest that the sub-coronary root replacement technique should be considered in elderly patients and patients with complex coronary anatomy.


Aortic Valve Insufficiency , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Male , Humans , Aged , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aorta/surgery , Heart Valve Prosthesis Implantation/methods , Reoperation
19.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Article En | MEDLINE | ID: mdl-38506737

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Aortic Valve Insufficiency , Bioprosthesis , Coronary Occlusion , Transcatheter Aortic Valve Replacement , Humans , Catheters , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Heart Valves , Registries , Transcatheter Aortic Valve Replacement/adverse effects
20.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article En | MEDLINE | ID: mdl-38532304

OBJECTIVES: Decellularized aortic homografts (DAH) were introduced as a new option for aortic valve replacement for young patients. METHODS: A prospective, EU-funded, single-arm, multicentre study in 8 centres evaluating non-cryopreserved DAH for aortic valve replacement. RESULTS: A total of 144 patients (99 male) were prospectively enrolled in the ARISE Trial between October 2015 and October 2018 with a median age of 30.4 years [interquartile range (IQR) 15.9-55.1]; 45% had undergone previous cardiac operations, with 19% having 2 or more previous procedures. The mean implanted DAH diameter was 22.6 mm (standard deviation 2.4). The median operation duration was 312 min (IQR 234-417), the median cardiopulmonary bypass time was 154 min (IQR 118-212) and the median cross-clamp time 121 min (IQR 93-150). No postoperative bypass grafting or renal replacement therapy were required. Two early deaths occurred, 1 due to a LCA thrombus on day 3 and 1 due ventricular arrhythmia 5 h postoperation. There were 3 late deaths, 1 death due to endocarditis 4 months postoperatively and 2 unrelated deaths after 5 and 7 years due to cancer and Morbus Wegener resulting in a total mortality of 3.47%. After a median follow-up of 5.9 years [IQR 5.1-6.4, mean 5.5 years. (standard deviation 1.3) max. 7.6 years], the primary efficacy end-points peak gradient with median 11.0 mmHg (IQR 7.8-17.6) and regurgitation of median 0.5 (IQR 0-0.5) of grade 0-3 were excellent. At 5 years, freedom from death/reoperation/endocarditis/bleeding/thromboembolism were 97.9%/93.5%/96.4%/99.2%/99.3%, respectively. CONCLUSIONS: The 5-year results of the prospective multicentre ARISE trial continue to show DAH to be safe for aortic valve replacement with excellent haemodynamics.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Endocarditis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Adult , Humans , Male , Allografts/surgery , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Endocarditis/surgery , Follow-Up Studies , Heart Valve Prosthesis Implantation/methods , Prospective Studies , Reoperation , Routinely Collected Health Data , Female , Adolescent , Young Adult , Middle Aged
...